BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//daytonashrae.org - ECPv6.17.0//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://daytonashrae.org
X-WR-CALDESC:Events for daytonashrae.org
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/New_York
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20220313T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20221106T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20230312T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20231105T060000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0500
TZOFFSETTO:-0400
TZNAME:EDT
DTSTART:20240310T070000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0400
TZOFFSETTO:-0500
TZNAME:EST
DTSTART:20241103T060000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20231009T173000
DTEND;TZID=America/New_York:20231009T193000
DTSTAMP:20231002T114656Z
CREATED:20230927T100833Z
LAST-MODIFIED:20231002T114656Z
UID:1416-1696872600-1696879800@daytonashrae.org
SUMMARY:Dayton ASHRAE Chapter Meeting (Research Promotion)
DESCRIPTION:Presentation: Basics of Air Change Rates (ACH): Facts versus Fiction (AIA and GBCI approved)\nPresenter: Kishor Khankari\, Ph.D.\, FASHRAE – President of AnSight\, LLC \nTheme: Research Promotion \nSocial Time: 5:30-5:55 PM\nChapter Business/Introductions: 5:55-6:00 PM\nDinner/Main Presentation: 6:00 PM \nPresenter Bio:\nDr. Kishor Khankari\, Ph.D. is President at AnSight LLC in Ann Arbor\, MI. He provides engineering solutions and insights through Physics based simulations and CFD analysis. Kishor has several years of experience in providing optimized HVAC solutions to a wide variety of applications involving external wind engineering\, plume dispersion\, smoke exhaust\, displacement ventilation\, natural ventilation\, radiant heating and cooling\, and indoor air quality and thermal comfort optimization for office spaces\, patient rooms\, operating rooms\, cleanrooms\, justice facilities\, data centers\, and warehouses. Dr. Khankari has developed a patented technology of a wind band design of exhaust fan assembly systems. He has developed several easy-to-use analytical software tools which are regularly used by design engineers in a variety companies including those in HVAC industry\, critical facilities\, and automotive industries.  \nA noted expert in his field\, he has a Ph.D. from the University of Minnesota and has been regularly published in several technical journals and trade magazines. Dr. Khankari has delivered more than 125 DL presentations worldwide on topics related to design and optimization of HVAC systems and made several presentation at various technical conferences and professional meetings.  \nDr. Kishor Khankari is a Fellow member of ASHRAE. He is currently serving on ASHRAE Board as a Director-at Large. He is a recipient of Louise & Bill Holladay Distinguished Fellow Award\, ASHRAE Exceptional and Distinguished Service Awards. He is the past President of Detroit ASHRAE Chapter\, past Chair of ASHRAE Technical Committee TC9.11 Clean Spaces\, and past Chair of Research Administration Committee (RAC). He is a voting member of Technical Committee TC9.10 Laboratory Systems and TC5.3 Air Distribution. He is a voting member of Standards committees SPC241: Control of Infectious Aerosols and SPC129: Air Change Effectiveness. He is also leading a Multi Task Group (MTG) on Air Change Rates. \nTopic Description:\nAir Changes per Hour (ACH) is often specified in ASHRAE standards\, codes\, design guidelines\, and handbooks for required ventilation rate. Examples of such spaces are patient rooms\, operating room\, bathrooms\, cleanroom\, and laboratories. This presentation will systematically demonstrate the validity of popular notions regarding the ACH. The role of space volume in controlling and distributing the contaminant in the space will be discussed. This presentation will further demonstrate whether ACH can’t be a sole criterion for effective ventilation of critical spaces using the examples for patient room\, hospital operating room\, laboratory spaces\, and cleanroom. A new concept for analyzing ventilation effectiveness for these spaces will be introduced to design and optimize the HVAC layout for healthcare\, laboratory\, and cleanroom facilities. In addition\, a role of demand control ventilation in minimizing the ACH will be discussed. This lecture will provide valuable insights to architects\, design engineers\, and facilities managers into the design and operation of critical facilities.
URL:https://daytonashrae.org/event/dayton-ashrae-chapter-meeting-10/
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=America/New_York:20231018T080000
DTEND;TZID=America/New_York:20231018T090000
DTSTAMP:20230927T100905Z
CREATED:20230927T100905Z
LAST-MODIFIED:20230927T100905Z
UID:1418-1697616000-1697619600@daytonashrae.org
SUMMARY:Dayton ASHARE Board of Governors Meeting
DESCRIPTION:
URL:https://daytonashrae.org/event/dayton-ashare-board-of-governors-meeting/
END:VEVENT
END:VCALENDAR